Webasto BCT010300C Repair Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 54
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
Troubleshooting – BlueCool Truck Electrical System
Webasto Product N.A., Inc. 16 www.techwebasto.com
Table 6. Symptom:
System begins operation after 1/2 hour delay period expires. Condenser fan DOES respond but refrigerant
compressor DOES NOT respond.
Symptom/Malfunction Inspection Remedy
Power inverter switched off Switch power inverter on.
Note: Green LED indicator will only illuminate
during an active system charge cycle.
Power inverter switching relay
not responding.
Check for power on pin-86 (blue wire) and ground on pin-85
(brown wire) of relay socket X11.
Refer to Fig. 22, on pg. 20.
Check for continuity across pin-87 and pin-30 of relay socket
X11.
Note: Power inverter switch must be in the OFF position and
the charging mode active in order to perform this check.
If no reading, repair open circuit, terminals or
damaged wiring between relay socket X10 and
X11.
If open circuit (OL), replace relay.
Power inverter on, green LED
on, no 110 volt AC output.
Check AC output at 110 Volt AC connector. Refer to Fig. 26,
on pg. 22.
If no output, replace inverter (internal fault).
Power inverter on, green LED
off, no 110 volt AC output.
Perform function test on switching relay. If relay is functioning normally, replace inverter
(internal fault).
110 volt AC wiring harness
contacts or open circuit.
Switch OFF power inverter. Check physical condition of 110 V
AC harness for loose/corroded connections and open circuits.
Repair as necessary.
Compressor overheat/
overload limiter defect
Switch OFF power inverter. Remove protection cap from top
of compressor and check wiring connections.
Perform continuity test across limiter terminals. Refer to Fig.
34, on pg. 34.
Check compressor function and electrical diagnosis. Refer to
Section 6 “Troubleshooting – Refrigerant Compressor”
Repair as necessary.
If open circuit (OL), replace limiter.
Repair or replace as defined in Section 6
“Troubleshooting – Refrigerant Compressor”
Table 7. Symptom:
System begins operation after 1/2 hour delay period expires but shuts down shortly after without
completing a full charge cycle.
Symptom/Malfunction Inspection Remedy
Power inverter switches off
during charging cycle
Low battery voltage.
Check all control circuit connections for loose terminals. Refer
to Table 5 on pg 15 and Table 6 on pg 16 for check points.
Clean battery posts, cables and frame ground connections
Load-test batteries.
Check power inverter battery cables and connections for
looseness or corrosion. Check voltage drop between batteries
and inverter.
Ensure inverter battery cables are installed as recommended in
the BlueCool Installation manual P/N BCT010031B
Charge batteries.
Repair or replace as necessary.
Repair or replace as necessary.
If voltage drop is greater than 0.5 volts, repair or
replace as necessary.
Correct cable connections as recommended by
Webasto.
If inverter continues to fault out, call Webasto
Product N.A., Inc. at 1-800-555-4518
Compressor overheat/
overload limiter responds
Check refrigerant pressures. Possible over-charge or blockage.
Check operation of condenser fan. Refer to Fig. 27, on pg.
22.
Check compressor function and electrical diagnosis. Refer to
Section 6 “Troubleshooting – Refrigerant Compressor”
Switch system off and allow compressor to cool.
(Cooling may take up to 1 hour before limiter will
self-reset). Service/repair refrigerant system and
recharge to specifications.
Repair or replace defective component.
Repair or replace as defined in Section 6
“Troubleshooting – Refrigerant Compressor”
Page view 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 53 54

Comments to this Manuals

No comments