Troubleshooting – Refrigerant Compressor
www.webasto.us 33 Webasto Product N.A., Inc.
6.4.2 Checking for Continuity and Proper
Resistance
If no ground fault has been detected using the
procedures in Section 6.4.1, determine whether there is
an open or short circuit in the motor windings or if the
heater element of the thermal protector is open.
Use the procedure in Table 10, “Checking for Proper
Continuity and Resistance,” on page 33 to check the
single phase motor.
Table 10. Checking for Proper Continuity and Resistance
Step 1: Allow Thermal Protector to
Reset
When servicing single compressors with internal thermal protectors, be sure
to allow time for the thermal protector to reset prior to starting these
electrical wiring checks. For some compressors, the internal thermal
protector may take as long as an hour to reset.
Step 2: Check Continuity Check the start winding by measuring continuity between terminal pins C
and S. (See “Identification of Hermetic Terminal” on page). If there is no
continuity, replace the compressor. See “System Cleanup and Compressor
Replacement After Compressor Failure” starting on page 36.
Check the run winding by measuring continuity between terminal pins C
and R. If there is no continuity, replace the compressor.
Step 3: Measure the Resistance Measure the resistance (ohms) between each pair of terminal pins: C and
S, C and R, and S and R. Add the resistance between C and S to the
resistance between C and R. This sum should equal the resistance found
between S and R. A small deviation in this comparison is acceptable.
Proper resistance may also be confirmed by comparing measured resistance
to the resistance specifications for the specific compressor model. Call 1-
800-211-3427 to request resistance specifications. If the resistance is not
correct, replace the compressor. See “System Cleanup and Compressor
Replacement After Compressor Failure” starting on page 36.
If the resistance is correct, leave the leads off and follow the instructions in
the next section to check other compressor electrical components.