Webasto BCT010300C Repair Manual Page 42

  • Download
  • Add to my manuals
  • Print
  • Page
    / 54
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 41
Component Replacement - Refrigeration Unit
Webasto Product N.A., Inc. 40 www.techwebasto.com
10. Install new compressor in reverse order of removal
and service system according to the precautions and
recommendations beginning with Section 6.2.9.
Figure 37. Compressor replacement
9.3 Condenser Replacement
Read over Section 9.1 before proceeding with condenser
replacement.
1. Switch the power inverter OFF.
2. Remove refrigeration unit cover.
Be sure refrigerant is recovered using the
appropriate equipment before removing the
condenser. Webasto recommends that the system
be serviced using a recovery, recycling and
recharging station such as a Robinair
® unit or
similar equipment designed for R134a refrigerant
systems.
3. Disconnect refrigerant lines from condenser. Protect
open lines with plastic caps or wrap to prevent the
ingress of moisture and contaminates.
4. Remove the top plate over the condenser (4 screws).
5. Remove the 2 screws and 2 nuts holding the right
side support to the base.
6. Remove the 3 screws holding the condenser to the
feft side support and pull condenser free.
7. Inspect condenser for possible contamination by dirt,
water, etc. If contaminated, service system
according to the precautions and recommendations
in Section 6.2.8 after replacing the condenser.
8. Install new condenser in reverse order of removal
and service system according to the precautions and
recommendations beginning with Section 6.2.9.
Figure 38. Condenser replacement
Torque
28.5 lb-ft.
Torque
27.5 lb-ft.
Torque
11.0 lb-in.
Torque
6.0 lb-ft.
Torque
12.5 lb-ft.
Torque
27.5 lb-ft.
Page view 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 53 54