Thermo Top E and Z/C 2 General Description
3
2.4 Control Unit / Heat Exchanger
The control unit / heat exchanger includes the
control unit
temperature sensor
overheat protection
heat exchanger
connector terminal.
CAUTION
The control unit / heat exchanger and the burner housing
represent an assembly and must not be disassembled.
2.4.1 Control Unit
The control unit is the central unit and ensures control and
monitoring of combustion operation.
The control unit is ventilated by means of a ventilation
hose routed from the combustion air collector
compartment of the burner.
2.4.2 Temperature Sensor
The temperature sensor senses the coolant temperature
in the heat exchanger of the heater as an electrical
resistance. This signal is routed to the control unit for
processing.
2.4.3 Overheat Protection
Overheat protection, controlled by a temperature resistor,
protects the heater against undue operating temperatures.
Overheat protection responds at a water temperature in
excess of 105° C and switches the heater off.
2.4.4 Heat Exchanger
The heat exchanger transfers the heat generated by
combustion to the coolant circuit.
2.5 Circulation Pump
(Thermo Top E and C only)
The circulation pump ensures circulation of the coolant
within the vehicle and heater coolant circuit. The pump is
activated by the control unit and is in continuous
operation.
Circulation Pump
2.6 Dosing Pump
The dosing pump is a combined delivery, dosing and
shut-off system for the fuel supply of the heater out of the
vehicle fuel tank.
Dosing Pump DP 2 for Fuel operated Heaters
Dosing Pump DP 30.2 for Diesel operated Heaters
Connector Terminal
Control Unit
Heat Exchanger
Page view 9