Page view 25
Thermo 230/231/300/301/350 Electrical connections
57
10.6. Legend for circuit diagrams
Diagnostic connector
Digital timer P:
with positive at connection 10= Continuous operation
with immediate heating
Connection 10 open = Variable heating duration
can be programmed
(10 min to 120 min);
Default setting 120 min
Plug assignment:
with connection to terminal 61 heating mode
Option
Plug
assignment
4-core
cable
7-core
cable
D1 0.75 gr 0.75 rt
D2 0.75 or 0.75 or
D3 0.75 gn 0.75 bl
D4 0.75 br 2.0 br
F1 Not occupied 2.0 sw
F2 Not occupied 2.0 rt/ws
Cable colours
bl
br
ge
gn
gr
or
rt
sw
vi
ws
blue
brown
yellow
green
grey
orange
red
black
violet
white
Cable cross-sections
< 7.5 m 7.5 - 15 m
0.75 mm
2
1.5 mm
2
1.0 mm
2
1.5 mm
2
1.5 mm
2
2.5 mm
2
2.5 mm
2
4.0 mm
2
4.0 mm
2
6.0 mm
2
Th23_EA_degbfr_g.book Seite 57 Dienstag, 15. Februar 2005 2:03 14