Webasto DBW 46 Service Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
BBW 46 / DBW 46
6 Functional Checkouts
601
6. Functional Checkouts
6.1 General
This section describes the tests and adjustments on the
heater in installed and removed condition to prove its
serviceability.
WARNING
The heater must not be operated in closed areas like
garages or workshops not provided with exhaust
ventilation facilities.
6.2 Adjustments
6.2.1Adjustment of CO
2
Contents
Changing the combustion air quantity preset by the
manufacturer is permitted and may be achieved by
rotating the air set screw.
Adjustment Procedure
Clockwise rotation: CO
2
contents decreases (prior to
measurement allow heater to operate for approx. 5 min).
Coarse setting: screw in until flush with surface, then
rotate screw back one turn.
NOTE
Perform adjustment in full load operation only. Set CO
2
adjustment value in combination with a smoke spot
number of close to "1".
6.3 Components Testing
6.3.1Temperature Sensor Resistance Check
During electrical testing with a digital multimeter the
temperature sensor should have the following resistance
in accordance with the diagram below.
Test current < 1 mA.
6.3.2Flame Sensor Check
During electrical testing with a digital multimeter the flame
sensor readings should be as follows:
flame sensor "dark" approx. 12 V or 24 V
flame sensor "bright" approx. 1 V.
500
750
1000
1250
1500
1750
–40 0 40 80 120
8035 Stockdorf
Steuergeraet
SG 1560/12V
23004
5HB 004 327-08
Nicht werfen !
Made in W.-Germany
A
BC D
654
321
876
432
5
1
2
1
2
1
D8
D7
Resistance
Water temperature
Heater On 12 V or 24 V
after 14...26 sec close to 1 V
Heater On 12 V or 24 V
after 14...26 sec close to 1 V
Heater On 12 V or 24 V
after 14...26 sec close to 1 V
Heater On 12 V or 24 V
after 14...26 sec close to 1 V
Page view 14